Beta
N.Y. MRE
Multiple Residence Law
Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Always check the official source for the current text.
§ 1 Short title
Section 1. Short title. This chapter shall be known as the "multiple
residence law."
§ 2 Legislative finding
§ 2. Legislative finding. It is hereby declared that intensive
occupation of multiple dwellings having three or more families,
inadequate provision for light and air, insufficient protection against
and defective provisions for escape from fire, as well as the amount of
improper sanitation existing in multiple dwellings throughout this state
are a menace to the health, safety, morals, welfare, and reasonable
comfort of its citizens; and that the establishment and maintenance of
proper housing standards requiring sufficient light, air, sanitation and
protection from fire hazards are essential to the public welfare.
Therefore the provisions hereinafter prescribed to provide more adequate
protection in the event of fire, and sufficient light, ventilation and
sanitation for certain multiple residence buildings are enacted and
their necessity in the public interest is hereby declared as a matter of
legislative determination.
§ 3 Application to certain municipalities
§ 3. Application to certain municipalities. 1. This chapter shall
apply to all cities of less than three hundred twenty-five thousand
population and to all towns and villages.
2. Whenever the word "municipality" occurs in this chapter, it shall
mean a city, town or village to which the chapter is applicable. The
words "charter," "ordinance," "resolution," "regulation," "building
code," "department of health," "department of water supply," "fire
department," "department," "board," "municipal engineer," "building
official," "corporation counsel," "municipal treasury," or "fire
limits," shall be construed as if followed by the words "or
corresponding authority of any municipality in which the dwelling or
location referred to is situated."
3. Wherever in this chapter the installation or maintenance of a fire
alarm system, fire detecting system, watchman's clock system, sprinkler
system, fire-escape system or part thereof is required or permitted,
such system or part thereof shall be constructed, installed, arranged
and maintained in a manner satisfactory to the department in accordance
with rules and regulations adopted by the commission pursuant to section
three hundred twenty-six of this chapter.
§ 4 Definitions
§ 4. Definitions. Words and terms used in this chapter shall have the
following meanings:
1. "Alteration." Any change in the structural parts or existing
facilities of any building or the moving of any building from one
location or position to another.
2. "Apartment," or "suite." That portion of a dwelling consisting of
one or more living rooms, and occupied by the members of a family, which
group of rooms is separated from all other groups within a dwelling.
3. "Basement." A story partly below the curb level but having at least
one-half of its height above the curb level. A basement shall be counted
as a story in determining height, except as otherwise provided in this
chapter.
4. "Boarding house," "furnished room house," "rooming house," or
"tourist house." A multiple dwelling, in which there are less than
thirty sleeping rooms occupied primarily by transients who are lodged
with or without meals, and in which there are provided such services as
are incidental to its use as a temporary residence. Also a dwelling two
or more stories in height, occupied by one or two families and with five
or more transient boarders, roomers or lodgers residing with any one
family.
5. "Cellar." An enclosed space in a dwelling having more than one-half
of its height below the curb level. However, where a dwelling is set
back from the curb level in such a manner that the enclosed space in the
dwelling is above the curb level but at least one-half of its height is
below the land immediately adjacent to the dwelling, such space shall be
deemed a cellar. A cellar shall not be counted as a story.
5-a. "Child caring institutions." Institutions for the residential
care of children operated by authorized agencies as defined by the
social welfare law.
6. "Commission." The state building code commission in the executive
department of the state of New York.
7. "Converted or conversion." A change from non-dwelling or private
dwelling use to multiple dwelling occupancy after July first, nineteen
hundred fifty-two.
8. "Court." A space, other than a yard, on the same lot as a dwelling
and open to the sky. "Inner court." A court not extending to a street or
yard. "Outer court." A court extending to a street or yard.
9. "Curb level." The level of the curb at the center of the front of
the building, for the purpose of measuring the height of any portion of
a building; except that where a building faces on more than one street,
the curb level is the average of the levels of the curbs at the center
of each front. Where no curb elevation has been established the mean
level of the land immediately adjacent to the dwelling shall be
considered the curb level, unless the municipal engineer shall establish
such curb level or its equivalent.
10. "Department." The department, bureau, division, agency or person
charged with the enforcement of this chapter.
11. "Dining bay," "dining recess" or "dinette." A recess used for
dining purposes off a living room, foyer or kitchen.
12. "Dormitory." Any room occupied for sleeping purposes by five or
more persons. A "cubicle" is a small, partially enclosed sleeping space
within a dormitory, with or without a window.
13. "Dwelling." A building or structure which is occupied in whole or
in part as the home, residence or sleeping place of one or more persons.
14. "Family." One or more persons with whom there may be not more than
four boarders, roomers or lodgers all living together in a common
household. A boarder, roomer or lodger residing within the family
household is a person who pays a consideration therefor and such
residence is not an incident of employment therein.
15. "Fire alarm system." An approved system of sounding a fire alarm
or alarms installed in such a manner that it can be operated manually
from any story.
"Fire-detecting system." An approved system which automatically
detects a fire or an abnormal rise in temperature and actuates a fire
alarm.
16. "Fire-escape." A combination of outside balconies and stairs of
incombustible materials, providing an unobstructed means of egress from
a building.
17. "Fireproof." Made of incombustible materials with standard
fire-resistive ratings not less than those required for a fireproof
multiple dwelling.
18. "Fireproof multiple dwelling." One in which the walls and other
structural members are of incombustible materials or assemblies meeting
all of the requirements of the local building code for fireproof
construction, if any, and if there be none, then of the state building
construction code for fireproof construction applicable to multiple
dwellings.
19. "Fire-retarded." Covered with metal lath plastered with two or
more coats of cement or gypsum plaster or otherwise protected against
fire with materials of standard fire-resistive ratings of at least one
hour. Fireproof or fire-resistive material shall always be accepted as
meeting any requirement for fire-retarding.
20. "Fire-resistive." Covered or protected with incombustible
materials of standard fire-resistive ratings of at least one hour.
Fireproofing or fire-retarding shall always be accepted as meeting any
requirement for "fire-resistive" materials.
21. "Fire-stair." A fireproof stair, enclosed in fireproof walls,
within the body of the building which it serves, to which access may be
had only through self-closing fireproof doors.
22. "Fire-stopping." The closing of concealed draft openings with
brick or other incombustible materials to form an effectual fire barrier
between stories, and between the ceiling of the upper story and the
space under the roof.
23. "Foyer." A space within an apartment or suite used as an entrance
hall directly from a public hall.
24. "Frame dwellings." A non-fireproof dwelling of which any
structural member of its exterior walls is of wood. A structural member
shall not be deemed to include the veneer or facing of any such wall.
25. "Height." The vertical distance of a dwelling from the curb level
to the level of the highest point of the roof beams, except that in the
case of pitched roofs, it is the vertical distance from the curb level
to the mean height level of the gable or roof above the vertical street
wall. An attic not used or arranged to be used for human occupancy shall
not be considered in measuring the height of a dwelling.
26. "Hotel." A dwelling in which there are thirty or more sleeping
rooms in one building or structure occupied primarily by transients who
are lodged with or without meals; and there are provided such services
as are incidental to the use thereof as a temporary residence.
27. "Kitchen." A space, fifty-nine square feet or more in floor area,
used for cooking or warming of food.
28. "Kitchenette." A space, less than fifty-nine square feet in floor
area, used for cooking or warming of food.
29. "Living room." Any room in a multiple dwelling except:
a. A public hall, public vestibule, public room or other public part
of a dwelling;
b. A hall, corridor or passageway entirely within an apartment or
suite;
c. A foyer, the floor area of which does not exceed ten percentum of
the total floor area of the apartment or suite;
d. A kitchenette;
e. A dining bay, dining recess or dinette fifty-five square feet or
less in area;
f. A bathroom or water-closet compartment.
30. "Local building code." The building code, if any, adopted or
enacted by a city, town or village and which is in force in such city,
town or village, or in such town or portion thereof outside the limits
of any village or city, respectively, or the state building construction
code where applicable with respect thereto.
31. "Lodging house." A dwelling, other than a hotel, in which persons
are housed in a dormitory or dormitories, whether or not the space for
sleeping accommodations therein is divided into cubicles, for a single
night or for less than a week at one time.
32. "Lot." A parcel or plot of ground which is or may be occupied
wholly or in part by a dwelling, including the spaces occupied by
accessory or other structures and any open or unoccupied spaces thereon,
but not including any part of an abutting public street or thoroughfare.
a. "Corner lot." A lot of which at least two adjacent sides abut for
their full length upon streets or public places not less than forty feet
in width. Any other lot is an "interior lot." That portion of a corner
lot in excess of one hundred feet from the widest street on which the
lot abuts shall be considered an interior lot.
b. "Front of a lot." That boundary line which abuts on the street, or,
if there be more than one street abutting, on the street designated by
the owner. "Rear of a lot" is the side opposite the front.
c. "Depth of a lot." The distance from the front of the lot to the
extreme rear line of the lot. The depth of an irregular-shaped lot is
its mean depth.
d. "Lot running through from street to street." A lot where the front
and rear lines abut for their entire lengths upon streets or open public
places. When either of such lines exceeds the other in length by more
than twenty per centum, that part of the lot contiguous to the excess
length of the longer line shall be deemed an interior lot.
e. "Back to back lots." Lots or portions of lots which are on opposite
sides of the same part of a rear line common to both and the opposite
street lines on which the lots front are parallel with each other or
make an angle with each other of not more than forty-five degrees.
33. "Multiple dwelling." A dwelling which is either rented, leased,
let or hired out, to be occupied, or is occupied as the temporary or
permanent residence or home of three or more families living
independently of each other, including but not limited to the following:
a tenament, flat house, maisonette apartment, apartment house, apartment
hotel, tourist house, bachelor apartment, studio apartment, duplex
apartment, kitchenette apartment, hotel, lodging house, rooming house,
boarding house, boarding and nursery school, furnished room house, club,
sorority house, fraternity house, college and school dormitory,
convalescent, old age or nursing homes or residences. It shall also
include a dwelling, two or more stories in height, and with five or more
boarders, roomers or lodgers residing with any one family.
34. "Non-fireproof dwelling." A dwelling which does not meet the
requirements for a fireproof dwelling.
35. "Occupied" or "used." Such terms shall be construed as if followed
by the words "or arranged, designed, or intended to be occupied or
used."
36. "Owner." Owner or owners of the freehold of the premises or lesser
estate therein, a mortgagee or vendee in possession, assignee of rents,
receiver, executor, trustee, lessee, agent, or any other person, firm or
corporation, directly or indirectly in control of a dwelling.
37. "Premises." Land, improvements and appurtenances or any part
thereof.
38. "Private dwelling." A dwelling occupied exclusively for residence
purposes by one or two families and having not more than four boarders,
roomers or lodgers residing with any one family.
39. "Public hall." A hall, corridor or passageway not within any
apartment or suite of private rooms. "Public vestibule." A hall not
within any apartment or suite or private rooms providing access to a
stair or elevator and not wider than seven feet nor longer than twice
the width of the stair or elevator shaft opening upon such hall.
40. "Public part" or "public room." A space available for common usage
or used exclusively for storage purposes or for mechanical equipment of
the dwelling.
41. "Section." A part of a multiple dwelling other than an apartment
or suite, separated as a unit from the rest of such dwelling by
fireproof construction.
42. "Shaft." A space extending through one or more stories of a
dwelling connecting a series of openings therein or any story or stories
and the roof, and includes exterior and interior shafts whether for air,
light, elevator, dumbwaiter or any other purpose.
43. "Shall." The word "shall" is always mandatory.
44. "Single-room occupancy." The occupancy by one or two persons of a
single room, or two or more rooms which are joined together separated
from all other rooms within an apartment in a multiple dwelling so that
the occupant or occupants thereof reside separately and independently of
the other occupant or occupants of the same apartment.
45. "Sprinkler system." A system of piping connected to one or more
sprinkler heads with fusible struts which will be constructed to fuse at
a specified temperature so as to discharge an effective spray to cover
the area to be sprinkled. Such system may be either an automatic wet
pipe type in which all pipes and sprinkler heads are at all times filled
with water when the building is occupied, or a dry pipe system in which
the pipes and sprinkler heads are filled with air, either compressed or
at atmospheric pressure, and the water supply is controlled by a
dry-pipe valve.
46. "Stair." A flight or flights of steps including any landings and
parts of public halls through which it is necessary to pass in going
from one level to another.
47. "Stair hall." A part of a public hall through which it is
necessary to pass in going from the end of one flight of steps to the
beginning of another but shall not include an area that is also used to
provide direct ingress to and egress from an apartment or suite.
48. "Story." A space between the level of one finished floor and the
level of the next higher finished floor, or, if the top story, of the
space between the level of the highest finished floor and the top of the
highest roof beams, or, if the first story, of the space between the
level of the finished floor and the finished ceiling immediately above.
For the purpose of measuring height by stories of dwellings erected on
or after July first, nineteen hundred fifty-two, one additional story
shall be added for each twelve feet or fraction thereof that the first
story exceeds fifteen feet in height, and for each twelve feet or
fraction thereof that any story above the first story exceeds twelve
feet in height.
49. "Street wall." A wall of a building, at any level, nearest to a
street line abutting the property.
50. "Suite." That portion of a dwelling consisting of one or more
living rooms and occupied by the members of a family, which group of
rooms is separated from all other groups within a dwelling.
51. "Window dimensions." The measurements between the stop-beads or,
if there are no stop-beads, between the sides and the head and sill of
the sash opening.
52. "Yard." An open space on the same lot with a dwelling between the
extreme rear line of the lot and the extreme rear wall of the dwelling.
§ 8 General application to all dwellings
§ 8. General application to all dwellings. Except as otherwise
specifically provided in this chapter, every multiple dwelling shall be
constructed and maintained in accordance with all applicable
requirements of this chapter and other applicable laws.
§ 9 Buildings converted or altered
§ 9. Buildings converted or altered. 1. On or after July first,
nineteen hundred fifty-two, no multiple dwelling shall be enlarged or
its lot diminished so that the yard or other unoccupied areas shall be
diminished in size or area below the minimum requirements of this
chapter.
2. A building not a dwelling, if converted on or after July first,
nineteen hundred fifty-two, to a multiple dwelling, shall thereupon
become subject to all the provisions of this chapter applicable to new
multiple dwellings of like class and kind. "Class" shall mean the use of
a multiple dwelling for either permanent or transient occupancy or both.
"Kind" shall mean the type of construction of a building, either
fireproof or non-fireproof.
3. No dwelling shall be altered or converted so as to be in violation
of any provision of this chapter relating to dwellings of like class and
kind, and, except as provided in subdivision four, a dwelling, altered
or converted to be occupied primarily for permanent-residence use, shall
comply with article three; and a dwelling converted or altered to be
occupied primarily for transient use shall comply with article four.
4. If any multiple dwelling three or more stories in height is altered
after July first, nineteen hundred fifty-three so as to increase its
height or bulk for living purposes or so as to increase the number of
living rooms by more than twenty per centum, such dwelling shall be made
to conform to the requirements of this chapter with respect to new
dwellings of like class and kind erected after such date.
5. It shall be unlawful to convert a frame dwelling to a multiple
residence, except that a frame dwelling not more than two stories and
attic in height and erected before July first, nineteen hundred
fifty-two, as a one-family or two-family residence may be converted to a
multiple dwelling for permanent occupancy by complying with article
three; and if such residence is converted to be occupied, as a rule, for
transient use, it shall comply with article four.
§ 10 Dwellings damaged
§ 10. Dwellings damaged. If an old or other existing multiple dwelling
be damaged by fire or other cause to the extent of two-thirds or more of
its value at the time of such damage exclusive of the value of the
foundation, such dwelling shall not be repaired or rebuilt except in
conformity with the provisions of this chapter relative to new multiple
dwellings.
§ 11 Old dwellings
§ 11. Old dwellings. Except as required in section nine and articles
three and four, nothing in this chapter shall be construed to require
any change in the construction, use, or occupancy of any old or other
existing multiple dwelling occupied as such on July first, nineteen
hundred fifty-two, which on such date is in compliance with the
provisions of all statutes, local laws, ordinances, rules and
regulations applicable thereto.
§ 12 Uncompleted dwellings
§ 12. Uncompleted dwellings. 1. The provisions of this chapter
relating to new multiple dwellings shall not apply to any multiple
dwelling for which plans were on file with the department or a permit to
commence building was issued by the department before July first,
nineteen hundred fifty-two, or to any dwelling the plans for conversion
of which to multiple dwelling occupancy, were on file with the
department or a permit authorizing the commencement of the work of such
conversion was issued by the department before such date, provided,
however, a certificate of occupancy as required by the provisions of
section three hundred two shall be obtained therefor prior to July
first, nineteen hundred fifty-seven.
2. No provisions of any part of this section shall be deemed to
prohibit the amendment of any plans filed and approved before July
first, nineteen hundred fifty-two, if such amendment would have been
lawful before such date, or if such amendment complies with the
requirements of this chapter for alterations to buildings of like kind
existing before such date.
§ 13 Prohibited uses: The storage or keeping of any combustible gaseous material within any multiple dwelling shall be unlawful unless a writt...
§ 13. Prohibited uses: The storage or keeping of any combustible
gaseous material within any multiple dwelling shall be unlawful unless a
written permit therefor is issued by the department and any and all
local laws or regulations applicable thereto are complied with. The
provisions of this section shall not prevent the keeping of such
gasoline, oil or other fuel as may be contained in a tank or receptacle
of a motor vehicle stored in a space provided for automobiles in a
multiple dwelling, nor shall this section apply to gaseous material used
for the cleaning or washing of a motor vehicle so stored. Such permit
shall not be required for the keeping or storage of oil or kerosene in
quantities not exceeding five gallons at any one time for domestic
heating or cooking purposes, provided such oil or kerosene is in a
container directly connected to the heating or cooking appliances in
which it is to be used and is kept or stored in accordance with
standards of safety prescribed by the department.
§ 15 Smoke detecting devices
§ 15. Smoke detecting devices. 1. This section shall apply to all
multiple dwellings, whenever constructed, provided however, that for the
purposes of this section the term "multiple dwelling" shall also include
any dwelling accommodation used as a temporary or permanent residence
located in any building owned as a condominium or cooperative.
2. (a) The owner of every multiple dwelling to which the provisions of
this section apply shall equip each apartment or other separate living
unit in such multiple dwelling with approved and operational smoke
detecting devices in conformity with the state fire prevention and
building code; provided, however, that any multiple dwelling not subject
to the provisions of such code may, in the alternative, be equipped with
battery-operated smoke detecting devices of a type accepted by the
division of housing and community renewal.
(b) In hotels, tourist houses, lodging houses, rooming houses,
boarding houses, boarding and nursery schools, furnished room houses,
club houses, sorority and fraternity houses, college and school
dormitories, convalescent, old age and nursing homes, any dwelling which
is two or more stories in height, with five or more boarders, roomers or
lodgers residing with any one family, and any multiple dwelling used for
single room occupancy, at least one smoke detecting device shall be
located within each room used for sleeping purposes. In any other
multiple dwelling or portion thereof, there shall be at least one smoke
detecting device located within each apartment or separate living unit,
in an area so that it is clearly audible in each bedroom or other room
used for sleeping purposes, with intervening doors closed; provided,
however, that no smoke detecting device be located more than ten feet
from the entrance to any bedroom or other room used for sleeping
purposes.
(c) Each smoke detecting device shall include a test device to permit
the occupant to readily determine if it is operational.
(d) In addition to complying with the provisions of this section, the
type, location, number, and manner of installation of smoke detecting
devices shall be in accordance with standards prescribed by the state
fire prevention and building code council.
3. (a) With respect to multiple dwellings which are occupied for
permanent residential purposes only, other than any portion of any such
dwelling used for single room occupancy, and notwithstanding the
provisions of sections forty and one hundred seventy-four or any other
provision of this chapter, or of any other law or requirement, state or
local, the duties of the owner and tenant with respect to smoke
detecting devices installed pursuant to this section shall be as
provided in subdivisions four and five of this section.
(b) With respect to multiple dwelling units as specified in paragraph
(b) of subdivision two of this section, or any portion of any multiple
dwelling used for single room occupancy, the provisions of subdivision
five of this section shall not apply, and smoke detecting devices
installed as required by this section shall be subject to the provisions
of section forty or one hundred seventy-four of this chapter.
(c) The owner of every multiple dwelling shall keep such records as
the state fire prevention and building code council shall prescribe
relating to the installation and maintenance of smoke detecting devices
in the building and make such records available to any local code
enforcement official on request.
4. In addition to initially providing and installing the smoke
detecting devices, the owner shall:
(a) replace within thirty days after the receipt of written notice any
such device which becomes inoperable within one year of the installation
of such device due to a defect in the manufacture of such device and
through no fault of the occupant of the apartment or other unit;
(b) upon the occurrence of a vacancy, replace or properly equip any
such device which has been removed or rendered inoperable, so as to
provide operational smoke detecting devices for any new tenant; and
(c) notify tenants in writing, individually or through posting of a
notice in a common area of the building, of the respective duties of
owners and tenants under this section.
5. Except as provided in paragraph (b) of subdivision three of this
section, the tenant shall keep and maintain any smoke detecting device
installed pursuant to this section in good repair and replace any such
device which becomes inoperable during his occupancy.
6. An owner need not furnish or install a smoke detecting device where
one has already been installed, provided that (a) the type of such
device and the manner of its installation comply with the provisions of
this section and the standards prescribed by the state fire prevention
and building code council, (b) the existing device is tested and found
to be operational, and (c) the existence of such device in lieu of an
owner-furnished device is noted on the records kept by the owner
pursuant to paragraph (c) of subdivision three of this section.
§ 16 Multiple residence emergency information
§ 16. Multiple residence emergency information. 1. In the case of an
emergency affecting a multiple residence, the owner or agent of such
multiple residence shall provide emergency service personnel, upon the
request of such emergency service personnel, including but not limited
to local police and fire departments, with the names and contact
information of all affected residents or occupants as listed in the
lease of such multiple residence as is required to ascertain the safety
of such residents or occupants. For the purposes of this section, an
emergency shall include but not be limited to fires, gas leaks, building
collapses, natural disasters, acts of terrorism and other events where
the physical safety of residents must be accounted for by ascertaining
their whereabouts.
2. The owner or agent of such multiple residence shall update the list
of names and contact information of all affected residents or occupants
of such multiple residence upon the execution of a new lease, lease
renewal or lease amendment, or where such owner is an authority as such
term is defined in section three of the public housing law, including
all such authorities established after the first day of January,
nineteen hundred thirty-nine, upon annual recertification. Specific and
informed written consent shall be obtained by the owner or agent of the
multiple residence from each occupant or resident each time the list is
updated and no occupant's or resident's name or contact information
shall be included in such list without their specific and informed
written consent. Written notice shall be provided to the occupant or
resident about the contact list and shall include but not be limited to
that such list is maintained by the owner and the potential impact of
opting-out.
3. Such list of names and contact information shall only be maintained
for the purpose of an emergency evacuation and shall not be
disseminated, used or accessed by emergency services personnel or
disseminated, used or accessed by the owner or agent of such multiple
residence for any other purposes.
§ 25 Application of article three
§ 25. Application of article three. The provisions of this article
shall apply to all multiple dwellings existing on July first, nineteen
hundred fifty-two, and shall also apply to dwellings converted to
multiple dwelling occupancy on or after July first, nineteen hundred
fifty-two, provided, however, that this article shall not apply to
hotels and similar dwellings in any city, town or village with respect
to which the provisions of article four are applicable. The provisions
of this article shall apply in addition to and not in substitution for
the provisions of article two. Provisions of this article shall be
complied with on or before July first, nineteen hundred fifty-four.
§ 26 Egress from dwellings
§ 26. Egress from dwellings. In every such dwelling three stories or
more in height there shall be from each story at least two independent
means of egress accessible to each apartment or suite. The first means
shall open into a public hall connected with a stair affording safe
access to a street, or to a yard, court or passageway affording
continuous, safe and unobstructed access to a street. The second means
shall be directly to a fire-escape or to an enclosed stair without
passing through the first means, except that where the first means
includes an interior stair which is closed off at each floor level by
fire-retarded construction with a fireproof self-closing door therein,
the second means may be another such interior stair or a fire-escape
directly accessible on the same story from a public hall therein whether
or not such public hall is also a part of the first means provided such
fire-escape is not a wire, chain, cable, vertical ladder or rope
fire-escape. In lieu of a second means of egress a sprinkler system may
be installed in the public halls and stairs.
Except as required by the provisions of article four of this chapter,
the second means of egress shall not be required in a multiple dwelling
of fireproof construction, six stories or less in height, erected before
July first, nineteen hundred fifty-two, if the egress arrangements
thereof complied with requirements of law applicable at the time the
dwelling was erected.
§ 27 Fire-escapes
§ 27. Fire-escapes. Wire, chain, cable, combustible, vertical ladder
or rope fire-escapes shall not be accepted as a required or alternative
means of egress and, unless such fire-escapes are supplemental to the
means of egress required by section twenty-six, they shall be removed
and replaced by a system of fire-escapes constructed and arranged as
provided in section one hundred thirty-three. All fire-escapes erected
on or after July first, nineteen hundred fifty-three, to serve as a
second means of egress shall be in conformity with the provisions of
section one hundred thirty-three. It shall be unlawful to remove any
fire-escape without permission from the department. Such system shall be
installed, arranged and maintained in a manner satisfactory to the
department and in accordance with rules adopted by the commission.
§ 28 Stairs and entrance halls
§ 28. Stairs and entrance halls. In every such dwelling three stories
or more in height the wood wainscoting and other combustible materials
on the wall and ceiling surfaces in all halls shall be removed and
replaced with incombustible or other fire-resistive materials. In lieu
of such removal, a sprinkler system may be installed in such halls or
such wainscoting and the combustible surfaces may be treated or covered
in a manner satisfactory to the department with a surface fire-retardant
approved by the department. In such a dwelling, however, any entrance
door and every door opening into any entrance hall, stair hall, or other
public hall connected therewith, shall be self-closing. Every interior
sash, or opening other than a door, in the walls or partitions of such
halls and every window therein not opening to the outer air shall be
sealed with fire-resistive materials.
§ 29 Dumbwaiter shafts
§ 29. Dumbwaiter shafts. In every such dwelling three stories or more
in height the doors of all dumbwaiter shafts shall be made self-closing
and be covered on the shaft side with fire-resistive material.
§ 30 Cellar ceilings
§ 30. Cellar ceilings. In every such dwelling three stories or more in
height the ceiling of the cellar, or of the lowest story if there be no
cellar, shall be fire-retarded, or be equipped with a sprinkler system,
unless such ceiling has already been plastered to the satisfaction of
the department.
§ 31 Inside cellar stairs
§ 31. Inside cellar stairs. Every stair leading from a cellar to the
floor above in all old multiple dwellings shall be enclosed with
fire-retarded partitions and shall be equipped with a fire-retarded
self-closing door located as the department may approve.
§ 32 Artificial lighting
§ 32. Artificial lighting. The owner shall provide a light or lights
in every public hall, stair and fire-stair on every floor so that every
such space shall be lighted adequately.
§ 40 Repairs and cleanliness
§ 40. Repairs and cleanliness. All old multiple dwellings shall be
maintained in conformity with the provisions of section one hundred
seventy-four.
§ 41 Water supply
§ 41. Water supply. Every such dwelling shall be provided with an
adequate supply of water obtained from the public water system or from a
source approved by the public health officer having jurisdiction.
§ 42 Water closet and bath accommodations
§ 42. Water closet and bath accommodations. Every water closet or
bathroom installed in such dwellings on or after July first, nineteen
hundred fifty-two, and in dwellings converted on or after such date,
shall be in conformity with the provisions of section one hundred
seventy-one.
§ 43 Plumbing and drainage
§ 43. Plumbing and drainage. Every such dwelling shall be provided
with facilities for the disposal of sewage, waterborne waste, and
excreta, and such facilities shall be connected with the public sewers,
if available and practicable; otherwise, such waste matter shall be
disposed of in a manner approved by the public health officer having
jurisdiction.
§ 50 Application of article four
§ 50. Application of article four. 1. As used in this article, the
term "transient dwellings" shall mean and include hotels, lodging
houses, boarding and nursery schools, sorority houses, fraternity
houses, college and school dormitories, convalescent, old age and
nursing homes, and dwellings used for single room occupancy. The term
"transient occupancy" shall mean the occupancy of a room for sleeping
purposes by the same person or persons for a period of ninety days or
less.
2. Except as provided in sections sixty-three and sixty-four with
respect to one and two story transient dwellings only, this article
shall apply to all transient dwellings three or more stories in height
and in existence on July first, nineteen hundred fifty-two, provided,
however, that the provisions of article two and sections fifty-three,
fifty-six and sixty-one of this article shall apply to new transient
dwellings.
3. As to such existing transient dwellings, the provisions of sections
fifty-six, sixty-one and sixty-two of this article shall be complied
with on or before July first, nineteen hundred fifty-four, and all other
sections of this article shall be complied with on or before July first,
nineteen hundred fifty-five.
§ 52 Public halls and stairs
§ 52. Public halls and stairs. The walls and ceiling of every entrance
hall, stair hall or other public hall, every hall or passage not within
an apartment or suite of rooms, every dumbwaiter, elevator, and, every
other shaft, including stairs, connecting more than two successive
stories, shall be sealed off from every other portion of the dwelling
with fire-retarded materials, or, in lieu thereof, except in the case of
elevator shafts, shall be equipped with an automatic sprinkler system.
Except as provided in subdivision five of section fifty-five, nothing
contained in this article shall be deemed to exempt an interior required
means of egress from the enclosure requirements or the equipment
provided for in this section. A fire-detecting system shall not be
acceptable for any of the requirements of this section.
§ 53 Storage compartments
§ 53. Storage compartments. There shall be one or more completely
enclosed compartments for the storage of mattresses, furniture, paints,
floor wax, linens, brooms, mops and other such inflammable or
combustible paraphernalia incidental to the occupancy and maintenance of
the dwelling, and such paraphernalia shall be stored in no other portion
of such dwelling. Such compartments shall be completely protected by an
automatic sprinkler system or a fire-detecting system. Closets which do
not exceed one hundred square feet in floor area may be used for the
temporary storage of such paraphernalia, except mattresses, furniture,
paints and insecticides containing inflammable materials and are
excluded from the requirements of this section. Where such storage
compartments are located at least thirty feet distant from such
dwelling, no sprinklers or fire-detecting system shall be required.
§ 54 Kitchens and pantries
§ 54. Kitchens and pantries. All kitchens and pantries serving
restaurants or dining rooms in a non-fireproof transient dwelling shall
be equipped with an automatic sprinkler system or a fire-detecting
system. Where such kitchens and pantries are located at least thirty
feet distant from such dwelling, no sprinkler or fire-detecting system
shall be required.
§ 55 Egress
§ 55. Egress. 1. In every transient dwelling to which this article is
applicable there shall be from each story at least two independent means
of egress accessible to each room, apartment or suite, except as
otherwise provided in section sixty-three with respect to two story
transient dwellings.
2. The first means of egress shall be an enclosed stair extending
directly to a street, or to a yard, court or passageway affording
continuous, safe and unobstructed access to a street, or by an enclosed
stair leading to the entrance story, which story shall have direct
access to a street. That area of the dwelling immediately above the
street level and commonly known as the main floor, where the occupants
are registered and the usual business of the dwelling is conducted,
shall be considered a part of the entrance story; and a required stair
terminating at such main floor or its mezzanine shall be deemed to
terminate at the entrance story. An elevator or an unenclosed escalator
shall not be acceptable as a required means of egress.
3. The second means of egress shall be by an additional enclosed
stair, conforming to the provisions of subdivision two of this section,
a fire-stair or an outside fire-escape. In a non-fireproof dwelling when
it is necessary to pass through a stair enclosure which may or may not
be a required means of egress to reach a required means of egress, such
stair enclosure and that part of the public hall or corridor leading
thereto from a room, apartment or suite, shall be fire-retarded as
provided in section fifty-two or protected by a sprinkler system; in a
fireproof dwelling only that part of the hall or corridor leading to
such stair enclosure need be so protected.
4. Where it is impractical in such existing transient dwellings to
provide a second means of egress, the department may order, in lieu of
the second means of egress, additional alteration to the first means of
egress and to shafts, stairs and other vertical openings as the
department may deem necessary to safeguard the occupants of the
dwelling, may require the public halls providing access to the first
means of egress to be equipped on each story with an automatic sprinkler
system, and, in non-fireproof dwellings, may also require automatic
sprinkler heads in the stair which serves as the only means of egress.
5. Nothing in this section shall be deemed to require the enclosure of
a stair which is ornamental provided such stair does not connect more
than two stories.
6. A stair, fire-stair or fire-escape supplementary to the egress
requirements of subdivisions two, three and four of this section need
not lead to the entrance story or to a street, or to a yard or a court
which leads to a street, provided the means of egress therefrom is
approved by the department.
7. A fire-detecting system shall not be acceptable for any of the
requirements of this section.
8. In lieu of enclosing stairways as required by subdivisions two and
three of this section, an automatic sprinkler system may be provided on
such stairs.
9. All fire-escapes erected on or after July first, nineteen hundred
fifty-three, in compliance with this section, shall be arranged,
constructed and maintained in accordance with the provisions of section
one hundred thirty-three. Such system shall be installed, arranged and
maintained in a manner satisfactory to the department and in accordance
with rules adopted by the commission. It shall be unlawful to remove any
fire-escape without permission from the department.
§ 56 Exit and directional signs
§ 56. Exit and directional signs. Every means of egress shall be
indicated by a sign reading "EXIT" in red letters at least eight inches
high on a white background, or vice versa, illuminated at all times
during the day and night by a red light of at least twenty-five watts or
equivalent illumination. Such light shall be maintained in a keyless
socket. On all stories where doors, openings or passageways giving
access to any means of egress are not visible from all portions of such
stories, directional signs shall be maintained in conspicuous locations,
indicating in red on a white background, or vice versa, the direction of
travel to the nearest means of egress. At least one sign shall be
visible from the doorway of each room or suite of rooms. Existing signs
and illumination may be accepted if, in the opinion of the department,
such existing signs and illumination serve the intent and purpose of
this section. Supplementary stairs, fire-stairs or fire-escapes which
do not lead to the entrance story or to a street or to a yard or court,
leading to a street, shall be clearly marked "NOT AN EXIT" in black
letters at least four inches high on a yellow background, and at the
termination of each such stair, fire-stair or fire-escape, there shall
be a directional sign indicating the nearest means of egress leading to
a street. All signs shall be constructed, located and illuminated in a
manner satisfactory to the department.
§ 56-A Posting of means of egress in hotels and motels
§ 56-a. Posting of means of egress in hotels and motels. On each floor
of every hotel or motel having two or more stories where the rooms or
suites are connected by an interior hallway there shall be posted by
each stairway, elevator or other means of egress a printed scale floor
plan of the particular story, which shall show all means of egress,
clearly labeling those to be used in case of fire. Such signs shall be
posted in other conspicuous areas throughout the building. Said floor
plan shall be no smaller than eight inches by ten inches and shall be
posted in such a manner that it cannot be readily removed.
§ 57 Vertical and horizontal openings
§ 57. Vertical and horizontal openings. In order to prevent the
vertical and horizontal spread of fire, smoke and gases, it shall, in
addition to other applicable provisions of this article, be necessary to
comply with the requirements of this section.
1. All doors opening from shafts, stair halls or stairs and the door
assemblies shall be fire-retarded with the doors self-closing and
without transoms or any other opening. Except in the case of elevator
shafts, such shafts, stair halls or stairs may be protected by an
automatic sprinkler system in lieu of fire retarding.
2. All other doors opening upon entrance halls or other public halls
or corridors in every part of the dwelling shall be self-closing, except
where such dwelling is equipped throughout with an approved type
automatic sprinkler or fire-detecting system. It shall be unlawful to
attach to or maintain on or about any door required to be self-closing
any device which prevents the self-closing of such door.
3. Every existing interior glazed sash, window or opening, other than
a door, or a fireproof sash, window or opening glazed with wire glass,
in any partition forming required enclosures around stairs or shafts
shall be removed and the openings closed up and fire-retarded.
§ 58 Cellar ceiling
§ 58. Cellar ceiling. The ceiling of the cellar shall be fire-retarded
or be equipped with a sprinkler system, or the entire cellar shall be
equipped with a fire-detecting system. Any room within the dwelling in
which a boiler or furnace is used for generating heat or hot water to
service the dwelling shall be enclosed with fire-retarded partitions and
every door opening therefrom and its assembly shall be fireproof with
the door self-closing. The ceiling of such room shall also be
fire-retarded or be equipped with a sprinkler system, or the room shall
be equipped with a fire-detecting system.
§ 59 Ventilation for shafts
§ 59. Ventilation for shafts. 1. There shall be provided in the roof
directly over each stair, fire-stair, dumbwaiter, elevator or similar
shaft which extends to or within one story of a roof, a ventilating
metal skylight of the cross-sectional area of such shaft. Such skylight
need not, however, exceed twenty square feet in area. Where an existing
skylight is smaller than the dimensions or area prescribed in this
subdivision, no structural change shall be required, but a ventilating
metal skylight fitting the existing opening in the roof shall be
sufficient. Every skylight shall be glazed with plain glass in the roof
of such skylight and shall be equipped with metal screens over and under
the skylight. In lieu of a skylight a window of the same area at the top
story shall be accepted.
2. Whenever there is a flooring of solid construction at the top of
any enclosed stair, fire-stair, elevator or similar shaft, openings
shall be left near the top of such shaft for ventilation. Such openings
shall provide at least two hundred eighty-eight square inches of
unobstructed ventilation and shall communicate directly with the outer
air, or be otherwise ventilated in accordance with the provisions of the
local building code.
3. It shall be unlawful to discharge into any such shaft any
inflammable or volatile gases, liquids or other thing or matter which
would endanger life.
§ 60 Bulkheads and scuttles
§ 60. Bulkheads and scuttles. 1. There shall be a fire-resistive
bulkhead in the roof over, or connecting directly by means of a public
hall with the highest portion of every stair extending to the highest
story below the main roof. Stairs leading to such bulkheads shall be
fire-retarded as required for other public stairs and shall have at the
top fireproof doors and assemblies with the doors self-closing. All
stairs to required bulkheads shall be provided with a guide or handrail.
A scuttle so constructed as to be readily opened may be substituted for
a bulkhead in dwellings not exceeding three stories and a basement in
height. Such scuttle shall be at least twenty-one inches in width and
twenty-eight inches in length, covered on the outside with metal and
provided with a stationary iron or steel ladder leading thereto.
2. When a dwelling has a pitched or sloping roof with a pitch or slope
of more than fifteen degrees, no bulkhead or scuttle, or stair or ladder
leading thereto shall be required.
3. A bulkhead door or scuttle shall never be locked with a key, but
may be fastened on the inside with movable rustproof bolts or hooks.
All key locks shall be removed.
4. Bulkheads and stairs leading thereto existing on July first,
nineteen hundred fifty-two, shall be permitted provided the stairs have
such angle of ascent and treads of such dimensions as may be approved by
the department.
§ 61 Fire alarm system; watchman
§ 61. Fire alarm system; watchman. 1. Except as provided in
subdivision three, in every transient dwelling containing thirty or more
sleeping rooms for transient occupancy, there shall be an interior fire
alarm system.
2. Except as provided in subdivision three, in every fireproof
transient dwelling containing fifty or more sleeping rooms for transient
occupants, and in every non-fireproof transient dwelling containing
thirty or more such rooms, when thirty-five per centum or more of such
rooms are occupied, there shall be, in addition to the interior fire
alarm system, one or more watchmen or clerks, employed by the owner,
whose duty it shall be to visit every portion of the dwelling at
frequent regular intervals between the hours of eleven p.m. and seven
a.m. for the purpose of detecting fire or other sources of danger and
giving immediate and timely warning thereof to all the occupants. There
shall be provided a watchman's clock system or other device to record
the movement of such watchman.
3. Where throughout such dwelling a fire-detecting system, or an
approved type automatic sprinkler system is provided which actuates a
fire alarm by the flow of water through such system so as to give
warning to all the occupants of the dwelling, and is installed in a
manner satisfactory to the department in conformity with rules and
regulations adopted by the commission, the provisions of subdivisions
one and two shall not be applicable.
§ 62 Miscellaneous provisions
§ 62. Miscellaneous provisions. 1. An existing sprinkler installation,
fire alarm, watchman's clock or fire-detecting system which has been
approved or accepted by the department having jurisdiction and installed
before July first, nineteen hundred fifty-two, in conformity with rules
and regulations adopted by the commission, shall, after inspection by
the said department, be deemed to be in compliance with the requirements
of this chapter.
2. Where a sprinkler system is required by this article, such system
shall be constructed to fuse at a temperature not higher than one
hundred sixty-five degrees Fahrenheit, spaced so as to protect the area
which is required to be sprinklered.
3. In furnace, boiler, laundry rooms and other parts of the dwelling
where high temperature usually prevails, sprinkler heads may fuse at a
higher temperature. Where such rooms are located at least thirty feet
distant from such dwelling, no sprinklers shall be required.
4. Except as otherwise provided in sections fifty-two and fifty-five,
an approved fire-detecting system shall be accepted as meeting any
requirement for a sprinkler system under this article.
§ 63 Two story transient dwellings
§ 63. Two story transient dwellings. 1. All nursing and convalescent
homes, homes for the aged, and boarding and nursery schools, two stories
in height, shall conform with all of the provisions of article four.
2. Except as provided in subdivision one of this section, the only
provisions of article four which shall apply to two story transient
dwellings in existence on July first, nineteen hundred fifty-two, shall
be sections sixty, sixty-one, sixty-five, title two and the following:
a. Every such transient dwelling shall have at least two means of
egress. The first means of egress shall be by an interior stair closed
off at the top or bottom. The second means of egress shall be by an
additional interior stair closed off at the top or bottom or a fire
stair or fire escape. A second means of egress shall not be required in
a dwelling containing less than thirty sleeping rooms if the sill of the
second story window does not exceed fourteen feet in vertical height
above the ground or other safe landing place immediately below such
window sill.
b. Where it is impractical in such transient dwellings to provide a
second required means of egress, the department may order, in lieu
thereof, additional alterations to the first means of egress and to
shafts, stairs and other vertical openings to safeguard the occupants of
the dwelling, may require the public halls providing access to the first
means of egress to be equipped on both stories with an automatic
sprinkler system, and may also require automatic sprinkler heads in the
stair which serves as the only means of egress.
c. Where two means of egress are required by this section and one is
an ornamental stair, the provision for closing off the stair at top or
bottom shall not be applicable to the ornamental stair.
§ 64 One story transient dwellings
§ 64. One story transient dwellings. The only provisions of article
four which shall apply to one story transient dwellings in existence on
July first, nineteen hundred fifty-two, shall be sections sixty,
sixty-one, sixty-five and title two.
§ 65 Artificial lighting
§ 65. Artificial lighting. The owner shall provide a light or lights
in every public hall, stair and fire-stair on every floor so that every
such space shall be lighted adequately.
§ 70 Repairs and cleanliness
§ 70. Repairs and cleanliness. Every transient dwelling shall be
maintained in conformity with the provisions of section one hundred
seventy-four.
§ 71 Water closet and bath accommodations
§ 71. Water closet and bath accommodations. Every water closet or
bathroom installed in transient dwellings on or after July first,
nineteen hundred fifty-two, and in transient dwellings converted on or
after such date shall be constructed in conformity with the provisions
of section one hundred seventy-one.
§ 72 Water supply; plumbing and drainage
§ 72. Water supply; plumbing and drainage. Every such dwelling shall
comply with the provisions of sections forty-one and forty-three.
§ 100 Application of article five
§ 100. Application of article five. All the provisions of this article
shall apply to every multiple dwelling of permanent or transient
occupancy erected on or after July first, nineteen hundred fifty-two,
and shall apply in addition to and not in substitution for the
provisions of article two, articles six or seven, and in the case of
transient dwellings, sections fifty-three, fifty-six, and sixty-one of
article four.
§ 101 Height and bulk
§ 101. Height and bulk. The height and bulk of any new multiple
dwelling shall be in accordance with the provisions of any applicable
local law, ordinance, resolution, code provision or regulation.
§ 102 Yards and courts
§ 102. Yards and courts. Yards and courts in connection with any such
multiple dwelling shall be in accordance with the provisions of any
applicable local law, ordinance, resolution, code provision or
regulation.
§ 103 Lighting and ventilation of rooms
§ 103. Lighting and ventilation of rooms. 1. Except as in this section
and in sections one hundred five, one hundred seventy-one and articles
three and four otherwise expressly provided, every living room shall
have at least one window opening directly upon a street, yard or court
upon the same lot as that occupied by the dwelling in which such room is
situated.
2. Nothing in this section shall be construed as prohibiting the
windows of any room from opening on a partially-enclosed terrace
provided such terrace opens directly to a street, yard or court and the
area of the front of the terrace which is open to the outer air is at
least equal to seventy-five per centum of the floor surface area of the
terrace.
3. No required window shall open upon any offset or recess less than
six feet in width except a window of a water-closet compartment,
bathroom, or stair or of a kitchenette.
4. The total window area in every living room shall be at least
one-tenth of the floor surface area of such room.
§ 104 Size of rooms
§ 104. Size of rooms. 1. Every living room, except kitchens, shall
contain at least eighty square feet of floor space and shall be not less
than eight feet in its least horizontal dimension. However, in every
permanently occupied dwelling, one living room in each apartment or
suite shall have at least one hundred thirty-two square feet of floor
space.
2. Every living room shall be at least seven and a half feet high, the
measurements in all cases to be taken from the finished floor to the
finished underside of the ceiling. Beams crossing the ceiling may be
disregarded if none of them extends below the ceiling more than six
inches.
§ 105 Cooking spaces
§ 105. Cooking spaces. 1. Every space which is intended, arranged or
designed for cooking or warming of food shall be either a kitchen or
kitchenette.
2. A kitchen or kitchenette shall be unlawful unless it is
constructed, arranged and maintained in compliance with the following
applicable provisions:
a. The ceiling and walls, exclusive of doors, of all kitchenettes
shall be fire-retarded or in lieu thereof such space shall be equipped
with one or more sprinkler heads to fuse at a temperature not higher
than two hundred twelve degrees Fahrenheit. Such heads shall be
connected to the water supply through a pipe of adequate size.
b. In every kitchen and kitchenette, all combustible material
immediately underneath or within one foot of any apparatus used for
cooking or warming of food shall be fire-retarded or covered with
fire-resistive material.
c. Every kitchenette shall be provided with a window opening upon a
street or upon a yard, court or shaft. Such window shall be at least one
foot wide, have a total area of at least three square feet and be at
least ten per centum of the superficial floor area of such kitchenette.
In lieu of such window, in such kitchenette it shall be lawful to
install a system of mechanical or gravity ventilation to provide at
least six changes per hour of the air volume of such kitchenette.
d. Every kitchenette may be equipped with a door or doors, provided
the lower portion of each such door has a metal grille containing at
least forty-eight square inches of clear openings or, in lieu of such a
grille, there are two clear open spaces, each of at least twenty-four
square inches, one between the floor and each such door, and the other
between the top of each such door and the head jamb.
§ 106 Rooms in cellars
§ 106. Rooms in cellars. It shall be unlawful to occupy all or any
part of a cellar for sleeping purposes, but all or part of such cellar
may be used for storage or other general utility purposes accessory to
the occupancy, use or man
The text continues in the official source.